HOUSTON METHODIST WEST PHASE II EXPANSION
After opening its doors just five years ago, Houston Methodist West Hospital is currently expanding its campus to better serve the community. To ensure the expected life cycle is realized for the Houston Methodist West Hospital Phase II Expansion, Zero/ Six provided construction administration services, including peer reviews, submittal/shop drawing reviews, and observation of the ongoing construction of building enclosure components twice a week to compare with the construction documents. Performance
testing of the installed enclosure systems included air/water infiltration testing and diagnostic nozzle testing of fenestrations to ensure the final product exceeded expectations.
Owner Houston Methodist Hospital System
Architect Page/ Contractor Vaughn Construction
Location Houston, TX
Type Expansion
Status 2018
Scope of Work Drawing Review, On-site QA/QC and Reporting, Commissioning of the Building Envelope, including Air Infiltration Testing per ASTM E783, Static Pressure Water Infiltration Testing per ASTM E1105, and Diagnostic Nozzle Water Testing per AAMA 501.2.
HEALTH EDUCATION CENTER
The construction of The University of Texas Medical Branch Health Education Center marks the first significant educational/academic building to be developed on the Galveston campus in almost 40 years. Zero/Six is currently providing preliminary construction documents, submittal, and RFI reviews pertaining to the exterior envelope to ensure an air and water tight facility and verify Texas Department of Insurance compliance with the design plans, the local Building Department and local building codes.
Owner The University of Texas Medical Branch Architect EYP Architecture & Engineering (Rendering provided by EYP)
Contractor Vaughn Construction
Location Galveston, TX
Type New Construction
Scale 162,000 SF
Status Spring 2019
Cost $90.4 million
Scope of Work Drawing Review, On-site QA/QC and Reporting, TDI Windstorm Inspections and Certification, Sound Monitoring, and Commissioning of the Building Envelope, including Roof Membrane Uplift Resistance Testing per ASTM E907, Air Infiltration Testing per ASTM
E783, Static Pressure Water Infiltration Testing per ASTM E1105, and Diagnostic Nozzle Testing